1 The user watchdog timer is disabled in factory configurations and during the
configuration cycle of the application configuration. It is enabled after the application
configuration enters user mode.
Quartus II Software Support
Implementation in your design requires a remote system upgrade interface between
the Cyclone IV device logic array and remote system upgrade circuitry. You must also
generate configuration files for production and remote programming of the system
configuration memory. The Quartus II software provides these features.
The two implementation options, ALTREMOTE_UPDATE megafunction and remote
system upgrade atom, are for the interface between the remote system upgrade
circuitry and the device logic array interface. Using the megafunction block instead of
creating your own logic saves design time and offers more efficient logic synthesis
and device implementation.
f For more information about the ALTREMOTE_UPDATE megafunction, refer to the
Remote Update Circuitry (ALTREMOTE_UPDATE) Megafunction User Guide.
Document Revision History
Table 8â28 lists the revision history for this chapter.
Table 8â28. Document Revision History (Part 1 of 2)
Date
May 2013
February 2013
October 2012
November 2011
December 2010
Version
1.7
1.6
1.5
1.4
1.3
Changes
â Added Table 8â6.
â Updated Table 8â9 to add new device options and packages.
â Updated Figure 8â16 and Figure 8â22 to include user mode.
â Updated the âDedicatedâ column for DATA[0] and DCLK in Table 8â19.
â Updated the âUser Modeâ and âPin Typeâ columns for DCLK in Table 8â20.
Updated Table 8â9 to add new device options and packages.
â Updated âAP Configuration Supported Flash Memoriesâ, âConfiguration Data
Decompressionâ, and âOverriding the Internal Oscillatorâ sections.
â Updated Figure 8â3, Figure 8â4, Figure 8â5, Figure 8â7, Figure 8â8, Figure 8â9,
Figure 8â10, and Figure 8â11.
â Updated Table 8â2, Table 8â8, Table 8â12, Table 8â13, Table 8â18, and Table 8â19.
â Added information about how to gain control of EPCS pins.
â Updated âResetâ, âSingle-Device AS Configurationâ, âSingle-Device AP
Configurationâ, and âOverriding the Internal Oscillatorâ sections.
â Added Table 8â7.
â Updated Table 8â6 and Table 8â19.
â Updated Figure 8â3, Figure 8â4, and Figure 8â5.
â Updated for the Quartus II software version 10.1 release.
â Added Cyclone IV E new device package information.
â Updated Table 8â7, Table 8â10, and Table 8â11.
â Minor text edits.
Cyclone IV Device Handbook,
Volume 1
May 2013 Altera Corporation
|
▷ |