Chapter 1: Cyclone IV Transceivers Architecture
Self Test Modes
BIST
Figure 1–73 shows the datapath for BIST incremental data pattern test mode. The BIST
incremental data generator and verifier are located near the FPGA fabric in the PCS
block of the transceiver channel.
Figure 1–73. BIST Incremental Pattern Test Mode Datapath
FPGA
Fabric
Transceiver
Transmitter Channel PCS
BIST Incremental
Pattern Generator
Tx Phase
Compensation
FIFO
Byte
Serializer
8B/10B
Encoder
Transmitter Channel PMA
Serializer
Receiver Channel PCS
BIST Incremental
Pattern Verifier
Rx
Compensation
FIFO
Byte
Ordering
Byte
Deserial-
izer
8B/10B
Decoder
Parallel
loopback
path
Word
Aligner
Receiver Channel PMA
De-
Receiver
serializer
CDR
The incremental pattern generator and verifier are 16-bits wide. The generated pattern
increments from 00 to FF and passes through the TX PCS blocks, parallel looped back
to RX PCS blocks, and checked by the verifier. The pattern is also available as serial
data at the tx_dataout port. The differential output voltage of the transmitted serial
data on the tx_dataout port is based on the selected VOD settings. The incremental
data pattern is not available to the FPGA logic at the receiver for verification.
The following are the transceiver channel configuration settings in this mode:
■ PCS-FPGA fabric channel width: 16-bit
■ 8B/10B blocks: Enabled
■ Byte serializer/deserializer: Enabled
■ Word aligner: Automatic synchronization state machine mode
■ Byte ordering: Enabled
The rx_bisterr and rx_bistdone signals indicate the status of the verifier. The
rx_bisterr signal is asserted and stays high when detecting an error in the data. The
rx_bistdone signal is asserted and stays high when the verifier either receives a full
cycle of incremental pattern or it detects an error in the receiver data. You can reset the
incremental pattern generator and verifier by asserting the tx_digitalreset and
rx_digitalreset ports, respectively.