9. SEU Mitigation in Cyclone IV Devices
This chapter describes the cyclical redundancy check (CRC) error detection feature in
user mode and how to recover from soft errors.
1 Configuration error detection is supported in all Cyclone® IV devices including
Cyclone IV GX devices, Cyclone IV E devices with 1.0-V core voltage, and
Cyclone IV E devices with 1.2-V core voltage. However, user mode error detection is
only supported in Cyclone IV GX devices and Cyclone IV E devices with 1.2-V core
voltage.
Dedicated circuitry built into Cyclone IV devices consists of a CRC error detection
feature that can optionally check for a single-event upset (SEU) continuously and
automatically.
In critical applications used in the fields of avionics, telecommunications, system
control, medical, and military applications, it is important to be able to:
■ Confirm the accuracy of the configuration data stored in an FPGA device
■ Alert the system to an occurrence of a configuration error
Using the CRC error detection feature for Cyclone IV devices does not impact fitting
or performance.
This chapter contains the following sections:
■ “Configuration Error Detection” on page 9–1
■ “User Mode Error Detection” on page 9–2
■ “Automated SEU Detection” on page 9–3
■ “CRC_ERROR Pin” on page 9–3
■ “Error Detection Block” on page 9–4
■ “Error Detection Timing” on page 9–5
■ “Software Support” on page 9–6
■ “Recovering from CRC Errors” on page 9–9
Configuration Error Detection
1 Configuration error detection is available in all Cyclone IV devices including
Cyclone IV GX devices, Cyclone IV E devices with 1.0-V core voltage, and
Cyclone IV E devices with 1.2-V core voltage.
© 2013 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos
are trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at www.altera.com/common/legal.html. Altera warrants performance of its
semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and
services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service
described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device specifications before relying
on any published information and before placing orders for products or services.
ISO
9001:2008
Registered
Cyclone IV Device Handbook,
Volume 1
May 2013
Feedback Subscribe