Chapter 2: Logic Elements and Logic Array Blocks in Cyclone IV Devices
2–7
Document Revision History
Each LAB can use two clocks and two clock enable signals. The clock and clock enable
signals of each LAB are linked. For example, any LE in a particular LAB using the
labclk1 signal also uses the labclkena1. If the LAB uses both the rising and falling
edges of a clock, it also uses both LAB-wide clock signals. Deasserting the clock
enable signal turns off the LAB-wide clock.
The LAB row clocks [5..0] and LAB local interconnect generate the LAB-wide
control signals. The MultiTrack interconnect inherent low skew allows clock and
control signal distribution in addition to data distribution.
Figure 2–6 shows the LAB control signal generation circuit.
Figure 2–6. Cyclone IV Device LAB-Wide Control Signals
Dedicated
6
LAB Row
Clocks
Local
Interconnect
Local
Interconnect
Local
Interconnect
Local
Interconnect
labclkena1
labclkena2
labclr1
synclr
labclk1
labclk2
syncload
labclr2
LAB-wide signals control the logic for the clear signal of the register. The LE directly
supports an asynchronous clear function. Each LAB supports up to two asynchronous
clear signals (labclr1 and labclr2).
A LAB-wide asynchronous load signal to control the logic for the preset signal of the
register is not available. The register preset is achieved with a NOT gate push-back
technique. Cyclone IV devices only support either a preset or asynchronous clear
signal.
In addition to the clear port, Cyclone IV devices provide a chip-wide reset pin
(DEV_CLRn) that resets all registers in the device. An option set before compilation in
the Quartus II software controls this pin. This chip-wide reset overrides all other
control signals.
Document Revision History
Table 2–1 shows the revision history for this chapter.
Table 2–1. Document Revision History
Date
November 2009
Version
1.0
Initial release.
Changes
November 2009 Altera Corporation
Cyclone IV Device Handbook,
Volume 1