English
Language : 

EP4CE30F29C7N Datasheet, PDF (103/488 Pages) Altera Corporation – Cyclone IV Device Handbook, Volume 1
Chapter 5: Clock Networks and PLLs in Cyclone IV Devices
Spread-Spectrum Clocking
5–41
Figure 5–26 shows the dynamic phase shifting waveform.
Figure 5–26. PLL Dynamic Phase Shift
SCANCLK
PHASESTEP
PHASEUPDOWN
PHASECOUNTERSELECT
PHASEDONE
a
b
c
d
PHASEDONE goes low
synchronous with SCANCLK
The PHASESTEP signal is latched on the negative edge of SCANCLK (a,c) and must remain
asserted for at least two SCANCLK cycles. Deassert PHASESTEP after PHASEDONE goes low.
On the second SCANCLK rising edge (b,d) after PHASESTEP is latched, the values of
PHASEUPDOWN and PHASECOUNTERSELECT are latched and the PLL starts dynamic
phase-shifting for the specified counters, and in the indicated direction. PHASEDONE is
deasserted synchronous to SCANCLK at the second rising edge (b,d) and remains low
until the PLL finishes dynamic phase-shifting. Depending on the VCO and SCANCLK
frequencies, PHASEDONE low time may be greater than or less than one SCANCLK cycle.
You can perform another dynamic phase-shift after the PHASEDONE signal goes from
low to high. Each PHASESTEP pulse enables one phase shift. PHASESTEP pulses must be
at least one SCANCLK cycle apart.
f For information about the ALTPLL_RECONFIG MegaWizard™ Plug-In Manager,
refer to the ALTPLL_RECONFIG Megafunction User Guide.
Spread-Spectrum Clocking
Cyclone IV devices can accept a spread-spectrum input with typical modulation
frequencies. However, the device cannot automatically detect that the input is a
spread-spectrum signal. Instead, the input signal looks like deterministic jitter at the
input of the PLL. PLLs of Cyclone IV devices can track a spread-spectrum input clock
as long as it is in the input jitter tolerance specifications and the modulation frequency
of the input clock is below the PLL bandwidth, that is specified in the fitter report.
Cyclone IV devices cannot generate spread-spectrum signals internally.
PLL Specifications
f For information about PLL specifications, refer to the Cyclone IV Device Datasheet
chapter.
October 2012 Altera Corporation
Cyclone IV Device Handbook,
Volume 1