Section 12 Serial Communication Interface with FIFO (SCIF)
Transmitting and Receiving Serial Data Simultaneously (Synchronous Mode): Figure 12.18
shows a sample flowchart for transmitting and receiving serial data simultaneously.
Initialization
Start of transmission and reception
Read TDFE flag in SCFSR
No
TDFE = 1?
Yes
Write transmit data to SCFTDR
Read TDFE and TEND flags
[1]
in SCFSR while they are 1, then
clear them to 0
Read ORER flag in SCLSR
ORER = 1?
No
Read RDF flag in SCFSR
No
RDF = 1?
Yes
Read receive data in
SCFRDR, and clear RDF
flag in SCFSR to 0
No
All data received?
Yes
[2]
Error handling
[3]
[1] SCIF status check and transmit data
write:
Read SCFSR and check that the
TDFE flag is set to 1, then write
transmit data to SCFTDR. Read the
TDFE and TEND flags while they are
1, then clear them to 0. The transition
of the TDFE flag from 0 to 1 can also
be identified by a TXI interrupt.
[2] Receive error handling:
Read the ORER flag in SCLSR to
identify any error, perform the
appropriate error handling, then clear
the ORER flag to 0.
Transmission/reception cannot be
resumed while the ORER flag is set
to 1.
[3] SCIF status check and receive data
read:
Read SCFSR and check that RDF =
1, then read the receive data in
SCFRDR, and clear the RDF flag to
0. The transition of the RDF flag from
0 to 1 can also be identified by an RXI
interrupt.
[4] Serial transmission and reception
continuation procedure:
To continue serial transmission and
reception, read 1 from the RDF flag
and the receive data in SCFRDR, and
clear the RDF flag to 0 before
receiving the MSB in the current
frame. Similarly, read 1 from the
TDFE flag to confirm that writing is
possible before transmitting the MSB
in the current frame. Then write data
to SCFTDR and clear the TDFE flag
to 0.
Yes
Clear TE and RE bits
in SCSCR to 0
[4]
End of transmission and reception
Note: When switching from a transmit operation
or receive operation to simultaneous
transmission and reception operations,
clear the TE and RE bits to 0, and then
set them simultaneously to 1.
Figure 12.18 Sample Flowchart for Transmitting/Receiving Serial Data
Rev. 4.00 Sep. 13, 2007 Page 293 of 502
REJ09B0239-0400