English
Language : 

SH7606 Datasheet, PDF (249/532 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperH™ RISC engine Family / SH7606 Series
Section 10 Power-Down Modes
Canceling with Reset: Software standby mode is canceled by a power-on reset. Keep the RES pin
low until the clock oscillation settles. The internal clock will continue to be output to the CKIO
pin.
10.6 Module Standby Mode
10.6.1 Transition to Module Standby Mode
Setting the MSTP bits in the standby control registers (STBCR2 to STBCR4) to 1 halts the supply
of clocks to the corresponding on-chip peripheral modules. This function can be used to reduce the
power consumption in normal mode.
In module standby mode, the states of the external pins of the on-chip peripheral modules change
depending on the on-chip peripheral module and port settings. Almost all of the registers retains
its previous state.
10.6.2 Canceling Module Standby Function
The module standby function can be canceled by clearing the MSTP bits in STBCR2 to STBCR4
to 0, or by a power-on reset.
Rev. 4.00 Sep. 13, 2007 Page 223 of 502
REJ09B0239-0400