English
Language : 

MC68HC912BD32 Datasheet, PDF (225/292 Pages) Freescale Semiconductor, Inc – Advance Information
Freescale Semiconductor, Inc.
Analog to Digital Converter
ATD Registers
ATD Registers
ATDCTL0 — Reserved
$0060
Bit 7
6
5
4
3
2
1
Bit 0
0
0
0
0
0
0
0
0
RESET:
0
0
0
0
0
0
0
0
Write to this register will abort current conversion sequence. READ: any
time, WRITE: any time.
ATDCTL1 — Reserved
$0061
Bit 7
6
5
4
3
2
1
Bit 0
0
0
0
0
0
0
0
0
RESET:
0
0
0
0
0
0
0
0
WRITE: write to this register has no meaning. READ: Special Mode only.
ATDCTL2 — ATD Control Register 2
$0062
Bit 7
6
5
4
3
2
1
Bit 0
ADPU
AFFC
AWAI
0
0
0
ASCIE
ASCIF
RESET:
0
0
0
0
0
0
0
0
The ATD control register 2 and 3 are used to select the power up
mode, interrupt control, and freeze control. Writes to these registers
abort any current conversion sequence.
Read or write anytime except ASCIF bit, which cannot be written.
Bit positions ATDCTL2[4:2] and ATDCTL3[7:2] are unused and
always read as zeros.
ADPU — ATD Disable
0 = Disables the ATD, including the analog section for reduction in
power consumption.
1 = Allows the ATD to function normally.
Software can disable the clock signal to the ATD converter and power
down the analog circuits to reduce power consumption. When reset
to zero, the ADPU bit aborts any conversion sequence in progress.
3-adc
Analog to Digital Converter
For More Information On This Product,
Go to: www.freescale.com
MC68HC912BD32 Rev 1.0