English
Language : 

UPSD3354DV-40U6 Datasheet, PDF (246/272 Pages) STMicroelectronics – fast 8032 MCU with programmable logic
DC and AC parameters
30 DC and AC parameters
UPSD33xx
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 161. Operating conditions (5 V devices)
Symbol
Parameter
Min.
Max.
Unit
VDD
Supply voltage
VCC, AVCC
4.5
5.5
V
3.0
3.6
Ambient operating temperature (industrial)
–40
85
°C
TA
Ambient operating temperature (commercial)
0
70
°C
t(s) Table 162. Operating conditions (3.3 V devices)
c Symbol
Parameter
Min.
Max.
Unit
du VCC, VDD, AVCC Supply voltage
ro Ambient operating temperature
P (industrial)
te TA
Ambient operating temperature
le (commercial)
3.0
3.6
V
–40
85
°C
0
70
°C
bso Table 163. AC signal letters for timing(1)
- O Letter
t(s) A
Address
C
Clock
uc D
Input Data
rod I
Instruction
PL
ALE
te N
RESET input or output
le P
PSEN signal
so Q
Output Data
Ob R
RD signal
Description
W
WR signal
M
Output Macrocell
1. Example: tAVLX = Time from Address Valid to ALE Invalid.
246/272
Doc ID 9685 Rev 7