285
if Working Register R12 (CH) is the destination operand, then ECh will be
used as the destination operand in the Op Code.
E
src
or
E
dst
Example
If Working Register R1 contains 34h (00111000b) and Working Register
R14 contains 4Dh (10001101b), the statement:
XOR R1, R14
Op Code: B2 1E
leaves the value BDh (10111101b) in Working Register R1. The Z, and V
flags are cleared, and the S Flag is set.
Example
If Working Register R4 contains F9h (11111001b), Working Register
R13 contains 7Bh, and Register 7Bh contains 6Ah (01101010b), the
statement:
XOR R4, @R13
Op Code: B3 4D
leaves the value 93h (10010011b) in Working Register R4. The S Flag is
set, and the Z, and V flags are cleared.
Example
If Register 3Ah contains the value F5h (11110101b) and Register 42h
contains the value 0Ah (00001010b), the statement:
XOR 3Ah, 42h
Op Code: B4 42 3A
leaves the value FFh (11111111b) in Register 3Ah. The S Flag is set, and
the C and V flags are cleared.