English
Language : 

HD6417034 Datasheet, PDF (448/691 Pages) Renesas Technology Corp – SuperH RISC ENGINE SH7032 AND SH7034
• Bit 7 (A/D End Flag (ADF)): ADF indicates that A/D conversion is completed.
Bit 7 (ADF)
0
1
Description
Cleared to 0 under the following conditions:
(Initial value)
• The CPU reads the ADF bit while the bit is set to 1, then writes 0 in the bit
• The ADI starts the DMAC and the A/D conversion register is accessed
Set to 1 at the following times:
• Single mode: When A/D conversion is complete
• Scan mode: When A/D conversion of all selected channels is complete
• Bit 6 (A/D Interrupt Enable (ADIE)): ADIE selects whether or not an A/D interrupt (ADI) is
requested when A/D conversion is completed.
Bit 6 (ADIE)
0
1
Description
The A/D interrupt (ADI) request is disabled
The A/D interrupt (ADI) request is enabled
(Initial value)
• Bit 5 (A/D Start (ADST)): ADST selects the start or halting of A/D conversion. Whenever the
A/D converter is operating, this bit is set to 1. It can also be set to 1 by the A/D conversion
trigger input pin (ADTRG).
Bit 5 (ADST)
0
1
Description
A/D conversion is halted
(Initial value)
• Single mode: A/D conversion is performed. This bit is automatically cleared
to 0 at the end of the conversion.
• Scan mode: A/D conversion starts and continues cyclically on the selected
channels until this bit is cleared to 0 by software, a reset, or standby mode.
• Bit 4 (Scan Mode (SCAN)): SCAN selects either scan mode or single mode for operation. See
section 14.4, Operation, for descriptions of these modes. The mode should be changed only
when the ADST bit is cleared to 0.
Bit 4 (SCAN)
0
1
Description
Single mode
Scan mode
(Initial value)
412