HD6417034 Datasheet, PDF (155/691 Pages) Renesas Technology Corp – SuperH RISC ENGINE SH7032 AND SH7034 | |||
|
◁ |
⢠Bits 15â8 (Reserved): These bits are always read as 0.
⢠Bit 7 (Compare Match Flag (CMF)): Indicates whether the values of RTCNT and the refresh
time constant register (RTCOR) match. When 0, the value of RTCNT and RTCOR do not
match; when 1, the value of RTCNT and RTCOR match.
Bit 7: CMF
0
1
Description
RTCNT value does not equal RTCOR value
(Initial value)
To clear CMF, the CPU must read CMF after it has been set to 1, then write a 0
in this bit
RTCNT value is equal to RTCOR value
⢠Bit 6 (Compare Match Interrupt Enable (CMIE)): Enables or disables the compare match
interrupt (CMI) generated when CMF is set to 1 in RTCSR (RTCNT value = RTCOR value).
When cleared to 0, the CMI interrupt is disabled; when set to 1, it is enabled.
Bit 6: CMIE
0
1
Description
Compare match interrupt request (CMI) is disabled
Compare match interrupt request (CMI) is enabled
(Initial value)
⢠Bits 5â3 (Clock Select Bits 2â0 (CKS2âCKS0)): These bits select the clock input to RTCNT
from among the seven types of clocks created by dividing the system clock (Ï). When the input
clock is selected with the CKS2âCKS0 bits, RTCNT starts to increment.
Bit 5: CKS2
0
1
Bit 4: CKS1
0
1
0
1
Bit 3: CKS0
0
1
0
1
0
1
0
1
Description
Clock input disabled
Ï/2
Ï/8
Ï/32
Ï/128
Ï/512
Ï/2048
Ï/4096
(Initial value)
⢠Bits 2â0 (Reserved): These bits are always read as 0. The write value should always be 0.