HD6417034 Datasheet, PDF (436/691 Pages) Renesas Technology Corp – SuperH RISC ENGINE SH7032 AND SH7034
Error handling
No
ORER = 1?
Yes
Overrun error handling
Clear ORER bit in SSR to 0
End
Figure 13.18 Sample Flowchart for Serial Receiving (cont)
Receive direction
Serial
clock
Serial
data
Bit 7 Bit 0
Bit 7 Bit 0 Bit 1
Bit 6 Bit 7
RDRF
ORER
RXI interrupt handler
RXI request reads data in RDR
and clears RDRF to 0
RXI request
1 frame
Overrun
error, ERI
request
Figure 13.19 Example of SCI Receive Operation
In receiving, the SCI operates as follows:
1. The SCI synchronizes with serial clock input or output and initializes internally.
2. Receive data is shifted into RSR in order from the LSB to the MSB. After receiving the data,
the SCI checks that RDRF is 0 so that receive data can be loaded from RSR into RDR. If this
check passes, the SCI sets RDRF to 1 and stores the received data in RDR. If the check does
not pass (receive error), the SCI operates as indicated in table 13.8. When the error flag is set
400