10.4.3 Synchronizing Mode
In synchronizing mode, two or more timer counters can be rewritten simultaneously (synchronized
preset). Multiple timer counters can also be cleared simultaneously using TCR settings
(synchronized clear). Synchronizing mode enables the general registers to be incremented with a
single time base. All five channels can be set for synchronous operation.
Procedure for Selecting Synchronizing Mode (figure 10.26):
1. Set 1 in the SYNC bit of the timer synchro register (TSNC) to use the channels in the
synchronizing mode.
2. When a value is written in TCNT in any of the synchronized channels, the same value is
simultaneously written in TCNT in the other channels.
3. Set the counter to clear with compare match/input capture using bits CCLR1 and CCLR0 in
TCR.
4. Set the counter clear source to synchronized clear using the CCLR1 and CCLR0 bits.
5. Set the STR bits in TSTR to 1 to start the TCNT count.
Select synchronizing
mode
Set synchronizing mode (1)
Synchronized preset
Synchronized clear
Set TCNT
Channel that
No
generated clear
(2)
source?
Yes
Select counter
(3)
clear source
Select counter
(4)
clear source
Synchronizing preset
Start counting
Counter clear
(5)
Start counting
(5)
Synchronized clear
Figure 10.26 Procedure for Selecting Synchronizing Mode