English
Language : 

MC9S12GRMV1 Datasheet, PDF (862/1292 Pages) Freescale Semiconductor, Inc – MC9S12G Family Reference Manual and Data Sheet
32 KByte Flash Module (S12FTMRG32K1V1)
Register
FSTAT
Table 25-41. Program P-Flash Command Error Handling
Error Bit
ACCERR
FPVIOL
MGSTAT1
MGSTAT0
Error Condition
Set if CCOBIX[2:0] != 101 at command launch
Set if command not available in current mode (see Table 25-27)
Set if an invalid global address [17:0] is supplied see Table 25-3)
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the global address [17:0] points to a protected area
Set if any errors have been encountered during the verify operation
Set if any non-correctable errors have been encountered during the verify
operation
25.4.6.6 Program Once Command
The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the
nonvolatile information register located in P-Flash. The Program Once reserved field can be read using the
Read Once command as described in Section 25.4.6.4. The Program Once command must only be issued
once since the nonvolatile information register in P-Flash cannot be erased. The Program Once command
must not be executed from the Flash block containing the Program Once reserved field to avoid code
runaway.
Table 25-42. Program Once Command FCCOB Requirements
CCOBIX[2:0]
000
001
010
011
100
101
FCCOB Parameters
0x07
Not Required
Program Once phrase index (0x0000 - 0x0007)
Program Once word 0 value
Program Once word 1 value
Program Once word 2 value
Program Once word 3 value
Upon clearing CCIF to launch the Program Once command, the Memory Controller first verifies that the
selected phrase is erased. If erased, then the selected phrase will be programmed and then verified with
read back. The CCIF flag will remain clear, setting only after the Program Once operation has completed.
The reserved nonvolatile information register accessed by the Program Once command cannot be erased
and any attempt to program one of these phrases a second time will not be allowed. Valid phrase index
values for the Program Once command range from 0x0000 to 0x0007. During execution of the Program
Once command, any attempt to read addresses within P-Flash will return invalid data.
MC9S12G Family Reference Manual, Rev.1.23
864
Freescale Semiconductor