English
Language : 

MC9S12GRMV1 Datasheet, PDF (614/1292 Pages) Freescale Semiconductor, Inc – MC9S12G Family Reference Manual and Data Sheet
Freescale’s Scalable Controller Area Network (S12MSCANV3)
Module Base + 0x00XC
7
6
5
4
3
2
1
0
R
DLC3
DLC2
DLC1
DLC0
W
Reset:
x
x
x
x
x
x
x
x
= Unused; always read “x”
Figure 18-35. Data Length Register (DLR) — Extended Identifier Mapping
Table 18-34. DLR Register Field Descriptions
Field
Description
3-0
DLC[3:0]
Data Length Code Bits — The data length code contains the number of bytes (data byte count) of the respective
message. During the transmission of a remote frame, the data length code is transmitted as programmed while
the number of transmitted data bytes is always 0. The data byte count ranges from 0 to 8 for a data frame.
Table 18-35 shows the effect of setting the DLC bits.
DLC3
0
0
0
0
0
0
0
0
1
Table 18-35. Data Length Codes
Data Length Code
DLC2
0
0
0
0
1
1
1
1
0
DLC1
0
0
1
1
0
0
1
1
0
DLC0
0
1
0
1
0
1
0
1
0
Data Byte
Count
0
1
2
3
4
5
6
7
8
18.3.3.4 Transmit Buffer Priority Register (TBPR)
This register defines the local priority of the associated message buffer. The local priority is used for the
internal prioritization process of the MSCAN and is defined to be highest for the smallest binary number.
The MSCAN implements the following internal prioritization mechanisms:
• All transmission buffers with a cleared TXEx flag participate in the prioritization immediately
before the SOF (start of frame) is sent.
• The transmission buffer with the lowest local priority field wins the prioritization.
In cases of more than one buffer having the same lowest priority, the message buffer with the lower index
number wins.
MC9S12G Family Reference Manual, Rev.1.23
616
Freescale Semiconductor