Table 19-27 Status Read Mode Return Commands
Pin Name I/O7
I/O6
Attribute
Normal
Command
end
error
identification
I/O5
Program-
ming error
I/O4
Erase
error
I/O3
I/O2
I/O1
I/O0
—
—
Program- Effective
ming or
address error
erase count
exceeded
Initial value 0
0
0
0
0
0
0
0
Indications Normal
Command Program- Erase
—
—
Count
Effective
end: 0
error: 1
ming
error: 1
exceeded: 1 address
Abnormal Otherwise: 0 error: 1
Otherwise: 0
Otherwise: 0 error: 1
end: 1
Otherwise: 0
Otherwise: 0
Note: I/O2 and I/O3 are undefined.
19.13.8 Status Polling
• The I/O7 status polling flag indicates the operating status in auto-program or auto-erase mode.
• The I/O6 status polling flag indicates a normal or abnormal end in auto-program or auto-erase mode.
Table 19-28 Status Polling Output Truth Table
Pin Names
I/O7
I/O6
I/O0 to I/O5
Internal Operation
in Progress
0
0
0
Abnormal End —
1
0
0
1
0
0
Normal End
1
1
0
19.13.9 Programmer Mode Transition Time
Commands cannot be accepted during the oscillation stabilization period or the programmer mode setup period. After the
programmer mode setup time, a transition is made to memory read mode.
Table 19-29 Command Wait State Transition Time Specifications
Item
Symbol
Min
Standby release (oscillation tosc1
10
stabilization time)
Programmer mode setup time tbmv
10
VCC hold time
t dwn
0
Max
Unit
—
ms
—
ms
—
ms
Rev.6.00 Oct.28.2004 page 613 of 1016