English
Language : 

M1AFS600-PQ208 Datasheet, PDF (55/334 Pages) Microsemi Corporation – Fusion Family of Mixed Signal FPGAs
Fusion Family of Mixed Signal FPGAs
3.3 V OFF
3.3 V Power Supply ON/OFF
3.3 V ON
VINITSTATE = 0
And PUB = 1
And TRST = 0
OFF State
3.3 V Off,
PUB Pull-Up,
TRST Pull-Down,
VREN Disabled
Sleep Mode
3.3 V On,
VREN Disabled
*RTCPSMMATCH = 1
Or PUB = 0
PUB = 0
Or TRST = 1
or TRST = 1
Standby Mode
3.3 V On,
RTC Enabled
VREN Disabled
VRPU = 0
And PUB = 1
And TRST = 0
VRINITSTATE = 1
or PUB = 0
or TRST = 1
Normal Operation
3.3 V on,
VREN Enable
3.3 V ON, 1.5 V ON (VR on)
VRPU = 0
And PUB = 1
And TRST = 0
And *RTC: CTRL_STAT:
xtal_en = 1
Note: * To enter and exit standby mode without any external stimulus on PUB or TRST, the vr_en_mat in the
CTRL_STAT register must also be set to 1, so that RTCPSMMATCH will assert when a match occurs; hence the
device exits standby mode.
Figure 2-31 • State Diagram for All Different Power Modes
When TRST is 1 or PUB is 0, the 1.5 V voltage regulator is always ON, putting the Fusion device in
normal operation at all times. Therefore, when the JTAG port is not in reset, the Fusion device cannot
enter sleep mode or standby mode.
To enter standby mode, the Fusion device must first power-up into normal operation. The RTC is enabled
through the RTC Control/Status Register described in the "Real-Time Counter (part of AB macro)"
section on page 2-35. A match value corresponding to the wake-up time is loaded into the Match
Register. The 1.5 V voltage regulator is disabled by setting VRPU to 0 to allow the Fusion device to enter
standby mode, when the 1.5 V supply is off but the RTC remains on.
Revision 4
2- 39