Table 2-57 details the settings available to control the prescaler values of the AV, AC, and AT pins. Note
that the AT pin has a reduced number of available prescaler values.
Table 2-57 • Prescaler Control Truth Table—AV (x = 0), AC (x = 1), and AT (x = 3)
Control Lines
Bx[2:0]
000 3
Scaling
Factor, Pad to
ADC Input
0.15625
LSB for an
8-Bit
Conversion1
(mV)
64
LSB for a
10-Bit
Conversion1
(mV)
16
LSB for a
12-Bit
Conversion1
(mV)
4
001
0.3125
32
8
2
010 3
0.625
16
4
1
011
1.25
8
2
0.5
100
2.5
4
1
0.25
101
5.0
2
0.5
0.125
110
10.0
1
0.25
0.0625
111
20.0
0.5
0.125
0.03125
Notes:
1. LSB voltage equivalences assume VAREF = 2.56 V.
2. Full Scale voltage for n-bit mode: ((2^n) - 1) x (LSB for a n-bit Conversion)
3. These are the only valid ranges for the Temperature Monitor Block Prescaler.
Full-Scale
Voltage in
10-Bit
Mode2
16.368 V
8.184 V
4.092 V
2.046 V
1.023 V
0.5115 V
0.25575 V
0.127875 V
Range Name
16 V
8V
4V
2V
1V
0.5 V
0.25 V
0.125 V
Table 2-58 details the settings available to control the MUX within each of the AV, AC, and AT circuits.
This MUX determines whether the signal routed to the ADC is the direct analog input, prescaled signal,
or output of either the Current Monitor Block or the Temperature Monitor Block.
Table 2-58 • Analog Multiplexer Truth Table—AV (x = 0), AC (x = 1), and AT (x = 3)
Control Lines Bx[4]
Control Lines Bx[3]
ADC Connected To
0
0
Prescaler
0
1
Direct input
1
0
Current amplifier temperature monitor
1
1
Not valid
Table 2-59 details the settings available to control the Direct Analog Input switch for the AV, AC, and AT
pins.
Table 2-59 • Direct Analog Input Switch Control Truth Table—AV (x = 0), AC (x = 1), and AT (x = 3)
Control Lines Bx[5]
Direct Input Switch
0
Off
1
On
Table 2-60 details the settings available to control the polarity of the signals coming to the AV, AC, and AT
pins. Note that the only valid setting for the AT pin is logic 0 to support positive voltages.
Table 2-60 • Voltage Polarity Control Truth Table—AV (x = 0), AC (x = 1), and AT (x = 3)*
Control Lines Bx[6]
Input Signal Polarity
0
Positive
1
Negative
Note: *The B3[6] signal for the AT pad should be kept at logic 0 to accept only positive voltages.