Section 2 CPU
16-Bit/32-Bit Displacement: When data is accessed by 16-bit or 32-bit displacement, the pre-
existing displacement value is placed in the memory table. Loading the immediate data when the
instruction is executed transfers that value to the register and the data is accessed in the indirect
indexed register addressing mode (table 2.7).
Table 2.7 Displacement Accessing
Classification
SH7050 Series CPU
Example of Conventional CPU
16-bit displacement MOV.W @(disp,PC),R0
MOV.W @(H'1234,R1),R2
MOV.W @(R0,R1),R2
..................
.DATA.W H'1234
Note: @(disp,PC) accesses the immediate data.
Rev. 5.00 Jan 06, 2006 page 28 of 818