SH7708 Datasheet, PDF (131/633 Pages) Renesas Technology Corp – SuperH™ RISC engine | |||
|
◁ |
When the priorities for multiple interrupt sources are set to the same level and such interrupts are
generated at the same time, they are handled according to the default order listed in table 6.4.
Updating of interrupt priority level setting registers A and B should only be performed when the
BL bit in the status register (SR) is set to 1. To prevent erroneous interrupt acknowledgment, first
read one or other of the interrupt priority level setting registers, then clear the BL bit to 0. This
will secure the necessary timing internally.
Table 6.4 Interrupt Exception Vectors and Rankings
Interrupt Source
INTEVT Interrupt Priority IPR (Bit
Priority within Default
Code (Initial Value) Numbers) IPR Setting Unit Priority
NMI
H'1C0 16
â
â
High
IRL IRL3âIRL0 = 0000 H'200 15
â
â
IRL3âIRL0 = 0001 H'220 14
â
â
IRL3âIRL0 = 0010 H'240 13
â
â
IRL3âIRL0 = 0011 H'260 12
â
â
IRL3âIRL0 = 0100 H'280 11
â
â
IRL3âIRL0 = 0101 H'2A0 10
â
â
IRL3âIRL0 = 0110 H'2C0 9
â
â
IRL3âIRL0 = 0111 H'2E0 8
â
â
IRL3âIRL0 = 1000 H'300 7
â
â
â
IRL3âIRL0 = 1001 H'320 6
â
â
IRL3âIRL0 = 1010 H'340 5
â
â
IRL3âIRL0 = 1011 H'360 4
â
â
IRL3âIRL0 = 1100 H'380 3
â
â
IRL3âIRL0 = 1101 H'3A0 2
â
â
IRL3âIRL0 = 1110 H'3C0 1
â
â
TMU0 TUNI0*1
H'400 0â15 (0)
IPRA (15â12) â
TMU1 TUNI1*1
H'420 0â15 (0)
IPRA (11â8) â
TMU2 TUNI2*1
H'440 0â15 (0)
IPRA (7â4) High
TMU2 TICPI2*2
H'460 0â15 (0)
IPRA (7â4) Low
Low
113
|
▷ |