F81867 Datasheet, PDF (58/315 Pages) Feature Integration Technology Inc. – 6 UARTs μSuper IO With 128 Bytes FIFO and Power Saving Functions
F81867
Temperature Interrupt Status Register ⎯ Index 61h
Bit
Name
R/W Reset Default
Description
7
Reserved
R/W -
0 Reserved
This bit gets 1 to indicate TEMP2 temperature sensor has exceeded
6
T2_OVT _STS R/W 3VCC 0 OVT limit or below the “OVT limit –hysteresis”. Write 1 to clear this bit,
write 0 to ignore.
This bit gets 1 to indicate TEMP1 temperature sensor has exceeded
5
T1_OVT _STS R/W 3VCC 0 OVT limit or below the “OVT limit –hysteresis”. Write 1 to clear this bit,
write 0 to ignore.
A one indicates TEMP0 temperature sensor has exceeded OVT limit or
4
T0_OVT _STS R/W 3VCC 0 below the “OVT limit –hysteresis”. Write 1 to clear this bit, write 0 will be
ignored.
3
Reserved
R/W -
0 Reserved
This bit gets 1 to indicate TEMP2 temperature sensor has exceeded
2
T2_EXC _STS R/W 3VCC 0 high limit or below the “high limit –hysteresis” limit. Write 1 to clear this
bit, write 0 to ignore.
This bit gets 1 to indicate TEMP1 temperature sensor has exceeded
1
T1_EXC _STS R/W 3VCC 0 high limit or below the “high limit –hysteresis” limit. Write 1 to clear this
bit, write 0 to ignore.
A one indicates TEMP0 temperature sensor has exceeded high limit or
0
T0_EXC _STS R/W 3VCC 0 below the “high limit –hysteresis” limit. Write 1 to clear this bit, write 0
will be ignored.
Temperature Real Time Status Register ⎯ Index 62h
Bit
Name
R/W Reset Default
Description
7
Reserved
R/W -
0 Reserved
Set when the TEMP2 exceeds the OVT limit. Clear when the TEMP2 is
6
T2_OVT
R/W 3VCC 0
below the “OVT limit –hysteresis” temperature.
Set when the TEMP1 exceeds the OVT limit. Clear when the TEMP1 is
5
T1_OVT
R/W 3VCC 0
below the “OVT limit –hysteresis” temperature.
4
T0_OVT
R/W 3VCC
0 Set when the TEMP0 exceeds the OVT limit. Clear when the TEMP0 is
below the “OVT limit –hysteresis” temperature.
3
Reserved
R/W -
0 Reserved
Set when the TEMP2 exceeds the high limit. Clear when the TEMP2 is
2
T2_EXC
R/W 3VCC 0
below the “high limit –hysteresis” temperature.
Set when the TEMP1 exceeds the high limit. Clear when the TEMP1 is
1
T1_EXC
R/W 3VCC 0
below the “high limit –hysteresis” temperature.
0
T0_EXC
R/W 3VCC
0 Set when the TEMP0 exceeds the high limit. Clear when the TEMP0 is
below the “high limit –hysteresis” temperature.
58
Dec, 2011
V0.12P