F81867
Auto FAN1 and FAN2 Boundary Hystersis Select Register ⎯ Offset 98h
Bit
Name
R/W Reset Default
Description
Boundary hysteresis. (0~15ºC)
7-4 FAN2_HYS
R/W 5VSB 4h Segment will change when the temperature over the boundary
temperature and below the ( boundary – hysteresis).
Boundary hysteresis. (0~15ºC)
3-0 FAN1_HYS
R/W 5VSB 4h Segment will change when the temperature over the boundary
temperature and below the ( boundary – hysteresis).
Auto FAN3 Boundary Hystersis Select Register ⎯ Offset 99h
Bit
Name
R/W Reset Default
Description
7-4
Reserved
-
-
- Reserved.
Boundary hysteresis. (0~15ºC)
3-0 FAN3_HYS
R/W 5VSB 2h Segment will change when the temperature over the boundary
temperature and below the ( boundary – hysteresis).
Fan3 Control Register ⎯ Offset 9Ah
Bit
Name
R/W Reset Default
7
Reserved
-
-
- Reserved.
Description
6 FREQ_SEL_ADD3 R/W 5VSB
This bit and FAN3_PWM_FREQ_SEL are used to select FAN3
PWM frequency. NEW_FREQ_SEL3 = { FREQ_SEL_ADD3,
FAN3_PWM_FREQ_SEL}
0 00: 23.5 KHz
01: 11.75 KHz
10: 5.875 KHz
11: 220 Hz
5 FREQ_SEL_ADD2 R/W 5VSB
This bit and FAN2_PWM_FREQ_SEL are used to select FAN2
PWM frequency. NEW_FREQ_SEL2 = { FREQ_SEL_ADD2,
FAN2_PWM_FREQ_SEL}
0 00: 23.5 KHz
01: 11.75 KHz
10: 5.875 KHz
11: 220 Hz