English
Language : 

SH7101 Datasheet, PDF (275/486 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
8. Multi-Function Timer Pulse Unit (MTU)
(19) Operation when Error Occurs during Phase Counting Mode Operation, and Operation
is Restarted in PWM Mode 2: Figure 8.102 shows an explanatory diagram of the case where an
error occurs in phase counting mode and operation is restarted in PWM mode 2 after re-setting.
MTU module
output
TIOC*A
1
2
RESET TMDR
(PCM)
3
TIOR
(1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
10 11
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM2) (1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
• Not initialized (cycle register)
TIOC*B
Port output
PEn
Hi-Z
PEn
Hi-Z
Note: n = 0 to 15
Figure 8.102 Error Occurrence in Phase Counting Mode, Recovery in PWM Mode 2
1 to 9 are the same as in figure 8.100.
10. Set PWM mode 2.
11. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev.2.00 Sep. 27, 2007 Page 241 of 448
REJ09B0394-0200