8. Multi-Function Timer Pulse Unit (MTU)
(16) Operation when Error Occurs during PWM Mode 2 Operation, and Operation is
Restarted in Phase Counting Mode: Figure 8.99 shows an explanatory diagram of the case
where an error occurs in PWM mode 2 and operation is restarted in phase counting mode after re-
setting.
MTU module
output
TIOC*A
1
2
3
RESET TMDR TIOR
(PWM2) (1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
Error PFC TSTR
occurs (PORT) (0)
10
TMDR
(PCM)
11
TIOR
(1 init
0 out)
• Not initialized (cycle register)
12 13
PFC TSTR
(MTU) (1)
TIOC*B
Port output
PEn
Hi-Z
PEn
Hi-Z
Note: n = 0 to 15
Figure 8.99 Error Occurrence in PWM Mode 2, Recovery in Phase Counting Mode
1 to 9 are the same as in figure 8.96.
10. Set phase counting mode.
11. Initialize the pins with TIOR.
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev.2.00 Sep. 27, 2007 Page 238 of 448