English
Language : 

SH7101 Datasheet, PDF (265/486 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
8. Multi-Function Timer Pulse Unit (MTU)
(9) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in PWM Mode 2: Figure 8.92 shows an explanatory diagram of the case where an
error occurs in PWM mode 1 and operation is restarted in PWM mode 2 after re-setting.
1
2
3
RESET TMDR TOER
(PWM1) (1)
MTU module
output
TIOC*A
4
TIOR
(1 init
0 out)
5
6
PFC TSTR
(MTU) (1)
7
Match
8
9
10 11 12
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM2) (1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
• Not initialized (cycle register)
TIOC*B
• Not initialized (TIOC*B)
Port output
PEn
Hi-Z
PEn
Hi-Z
Note: n = 0 to 15
Figure 8.92 Error Occurrence in PWM Mode 1, Recovery in PWM Mode 2
1 to 10 are the same as in figure 8.90.
11. Set PWM mode 2.
12. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Note: PWM mode 2 can only be set for channels 0 to 2, and therefore TOER setting is not
necessary.
Rev.2.00 Sep. 27, 2007 Page 231 of 448
REJ09B0394-0200