8. Multi-Function Timer Pulse Unit (MTU)
(4) Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in Phase Counting Mode: Figure 8.87 shows an explanatory diagram of the case
where an error occurs in normal mode and operation is restarted in phase counting mode after re-
setting.
MTU module
output
TIOC*A
1
2
3
RESET TMDR TOER
(normal) (1)
4
TIOR
(1 init
0 out)
5
6
PFC TSTR
(MTU) (1)
7
8
9
10 11
Match Error PFC TSTR TMDR
occurs (PORT) (0) (PCM)
12
TIOR
(1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
TIOC*B
Port output
PEn
Hi-Z
PEn
Hi-Z
Note: n = 0 to 15
Figure 8.87 Error Occurrence in Normal Mode, Recovery in Phase Counting Mode
1 to 10 are the same as in figure 8.84.
11. Set phase counting mode.
12. Initialize the pins with TIOR.
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Note: Phase counting mode can only be set for channels 1 and 2, and therefore TOER setting is
not necessary.
Rev.2.00 Sep. 27, 2007 Page 226 of 448