C508_01 Datasheet, PDF (180/267 Pages) Infineon Technologies AG – 8-Bit CMOS Microcontroller
C508
On-Chip Peripheral Components
If either of these two conditions is not met, the received frame is irretrievably lost. If both
conditions are met, the stop bit goes into RB8, the eight data bits go into SBUF, and RI
is activated. At this time, whether the above conditions are met or not, the unit resumes
looking for a 1-to-0 transition in RxD.