Chapter 23 Voltage Regulator (S12VREGL3V3V1)
Table 23-13. Interrupt Vectors
Interrupt Source
Low-voltage interrupt (LVI)
High Temperature Interrupt (HTI)
Autonomous periodical interrupt (API)
Local Enable
LVIE = 1; available only in Full Performance
Mode
HTIE=1;
available only in Full Performance Mode
APIE = 1
23.4.11.1 Low-Voltage Interrupt (LVI)
In FPM, VREG_3V3 monitors the input voltage VDDA. Whenever VDDA drops below level VLVIA, the
status bit LVDS is set to 1. On the other hand, LVDS is reset to 0 when VDDA rises above level VLVID. An
interrupt, indicated by flag LVIF = 1, is triggered by any change of the status bit LVDS if interrupt enable
bit LVIE = 1.
NOTE
On entering the Reduced Power Mode, the LVIF is not cleared by the
VREG_3V3.
23.4.11.2 HTI - High Temperature Interrupt
In FPM VREG monitors the die temperature TDIE. Whenever TDIE exceeds level THTIA the status bit
HTDS is set to 1. Vice versa, HTDS is reset to 0 when TDIE get below level THTID. An interrupt, indicated
by flag HTIF=1, is triggered by any change of the status bit HTDS if interrupt enable bit HTIE=1.
NOTE
On entering the Reduced Power Mode the HTIF is not cleared by the VREG.
23.4.11.3 Autonomous Periodical Interrupt (API)
As soon as the configured timeout period of the API has elapsed, the APIF bit is set. An interrupt, indicated
by flag APIF = 1, is triggered if interrupt enable bit APIE = 1.
MC9S12XE-Family Reference Manual Rev. 1.25
Freescale Semiconductor
829