XRT79L71
1-CHANNEL DS3/E3 ATM UNI/PPP/CLEAR-CHANNEL FRAMER IC - REGISTER/MAP DESCRIPTION
BIT NUMBER
NAME
7-0
Transmit User Cell Filter
# 2 - Filtered Cell
Count[15:8]
TYPE
RUR
DESCRIPTION
Transmit User Cell Filter # 2 - Filtered Cell Count[15:8]:
These RESET-upon-READ bit-fields, along with that in the
Transmit ATM Cell Processor Block - Transmit User Cell Filter #
2 - Filtered Cell Count - Bytes 3, 2 and 0 register contain a 32-bit
expression for the number of User Cells that have been filtered
by Transmit User Cell Filter # 2 since the last read of this regis-
ter.
Depending upon the configuration settings within the Transmit
ATM Cell Processor Block - Transmit User Cell Filter Control -
Transmit User Cell Filter # 2 Register (Address = 0x1F63), these
register bits will be incremented anytime Transmit User Cell Fil-
ter # 2 performs any of the following functions.
• Discards an incoming User Cell.·
• Copies (or Replicates) an incoming User Cell and routes the
copy to the Transmit Cell Extraction Buffer.
• Both of these actions.
NOTE:
If the number of filtered cells reaches the value
"0xFFFFFFFF" then these registers will saturate to and
remain at this value (e.g., it will not overflow to
"0x00000000").
Transmit ATM Cell Processor Block - Transmit User Cell Filter # 2 - Filtered Cell Count - Byte 0
(Address = 0x1F6F)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Transmit
User Cell Fil-
ter # 2 - Fil-
tered Cell
Count[7:0]
RUR
RUR
RUR
RUR
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
0