English
Language : 

XRT79L71_1 Datasheet, PDF (121/434 Pages) Exar Corporation – 1-CHANNEL DS3/E3 ATM UNI/PPP/CLEAR-CHANNEL FRAMER IC -
REV. 1.0.0
XRT79L71
1-CHANNEL DS3/E3 ATM UNI/PPP/CLEAR-CHANNEL FRAMER IC - REGISTER/MAP DESCRIPTION
BIT NUMBER
NAME
0
Change in AIS Defect
Condition Interrupt Status
TYPE
RUR
DESCRIPTION
Change in AIS Defect Condition Interrupt Status:
This RESET-upon-READ bit-field indicates whether or not the
Change in AIS Defect Condition Interrupt has occurred since the
last read of this register.
f this interrupt is enabled, then the Receive E3 Framer block will
generate the Change in AIS State Interrupt will occur in response
to the following events.
• When the Receive E3 Framer block declares the AIS Defect
Condition.
• When the Receive E3 Framer block clears the AIS Defect
Condition.
0 - Indicates that the Change in AIS Defect Condition Interrupt
has not occurred since the last of this register.
1 - Indicates that the Change in AIS Defect Condition Interrupt
has occurred since the last read of this register.
NOTE:
The user can determine the current state of the AIS
Defect Condition by reading out the contents of Bit 3
(AIS Defect Condition Declared) within the Receive E3
Configuration and Status Register # 2 - G.832 (Address
= 0x1111).
Receive E3 Interrupt Status Register # 2 - G.832 (Address = 0x1115)
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
Unused
Change in
Receive
Trail-Trace
Message
Interrupt
Status
Reserved
Detection of
FEBE/REI
Event
Interrupt
Status
Change in
FERF/RDI
Defect
Condition
Interrupt
Status
Detection of
BIP-8 Error
Interrupt
Status
Detection of
Framing
Byte
Error
Interrupt
Status
R/O
RUR
R/O
RUR
RUR
RUR
RUR
0
0
0
0
0
0
0
BIT 0
RxPLD
Mismatch
Interrupt
Status
RUR
0
BIT NUMBER
NAME
7
Unused
TYPE
R/O
DESCRIPTION
112