Capture/Compare Unit 6 (CAPCOM6)
18.11 Interfaces of the CAPCOM6 Unit
The CAPCOM6 units is connected to its environment in different ways.
Internal Connections
The 4 interrupt request lines of the CAPCOM6 unit are connected to the interrupt control
block.
The period match signal of timer T13 (T13_PM) is connected to the ADC, as a possible
trigger source for injected conversions.
External Connections
The signals of the CAPCOM6 unit are connected with input/output ports of the XC164.
These ports may provide capture trigger signals from the external system, issue
compare output signals to external circuitry, or accept control input signals.
System
Control
Unit (SCU)
f
CC6
CC6DIS
CAPCOM6
Module
Interrupt
Control
CCU6IRQ
I0
CCU6EIRQ
I1
CCU6T12IRQ
I2
CCU6T13IRQ
I3
ADC
CCU6T13PM
CC60
COUT60
CC61
CCOUT61
CC62
CCOUT62
CCOUT63
CTRAP
CC6POS0
CC6POS1
CC6POS2
P1L.0
P1L.1
P1L.2
P1L.3
P1L.4
P1L.5
P1L.6
P1L.7
P1H.0
P1H.1
P1H.2
MCA05550
Figure 18-46 CAPCOM6 Unit Interfaces