Capture/Compare Units
17.3
Capture/Compare Channels
The 16-bit capture/compare registers CC0 through CC15 (CC16 through CC31) are
used as data registers for capture or compare operations with respect to timers T0/T7
and T1/T8. The capture/compare registers are not bit-addressable.
The functions of the 16 capture/compare registers of a unit are controlled by 4 bit-
addressable 16-bit mode control registers, named CC1_M0 … CC1_M3 (CC2_M4 …
CC2_M7), which are all organized identically (see description below). Each register
contains the bits for mode selection and timer allocation for four capture/comp. registers.
Capture/Compare Registers for the CAPCOM1 Unit (CC15 … CC0)
CC1_M0
CAPCOM Mode Ctrl. Reg. 0
SFR (FF52H/A9H)
15 14 13 12 11 10 9 8 7 6 5 4
ACC
3
rw
MOD3
rw
ACC
2
rw
MOD2
rw
ACC
1
rw
MOD1
rw
Reset Value: 0000H
3210
ACC
0
rw
MOD0
rw
CC1_M1
CAPCOM Mode Ctrl. Reg. 1
SFR (FF54H/AAH)
15 14 13 12 11 10 9 8 7 6 5 4
ACC
7
rw
MOD7
rw
ACC
6
rw
MOD6
rw
ACC
5
rw
MOD5
rw
Reset Value: 0000H
3210
ACC
4
rw
MOD4
rw
CC1_M2
CAPCOM Mode Ctrl. Reg. 2
SFR (FF56H/ABH)
15 14 13 12 11 10 9 8 7 6 5 4
ACC
11
rw
MOD11
rw
ACC
10
rw
MOD10
rw
ACC
9
rw
MOD9
rw
Reset Value: 0000H
3210
ACC
8
rw
MOD8
rw
CC1_M3
CAPCOM Mode Ctrl. Reg. 3
SFR (FF58H/ACH)
15 14 13 12 11 10 9 8 7 6 5 4
ACC
15
rw
MOD15
rw
ACC
14
rw
MOD14
rw
ACC
13
rw
MOD13
rw
Reset Value: 0000H
3210
ACC
12
rw
MOD12
rw
User’s Manual
CC12_X41, V2.1
17-10