English
Language : 

XC164-16 Datasheet, PDF (217/417 Pages) Infineon Technologies AG – 16-Bit Single-Chip Microcontroller with C166SV2 Core Volume 2 (of 2): Peripheral Units
Field
WHE
CHE
TRPS1)
TRPF
T13PM
T13CM
T12PM
T12OM
XC164-16 Derivatives
Peripheral Units (Vol. 2 of 2)
Capture/Compare Unit 6 (CAPCOM6)
Bits Type Description
13
rh
Wrong Hall Event Flag
0 No wrong hall pattern yet
1 A transition to a wrong hall pattern (not the
expected one) has occurred
12
rh
Correct Hall Event Flag
0 No correct (= expected) hall pattern yet
1 A transition to an expected hall pattern has
occurred
11
rh
Trap State Bit
0 The Trap State is not active
1 The Trap State is active. Bit TRPS is set while
bit TRPF = 1. It is reset according to the mode
selected in register TRPCTR.
10
rh
Trap Flag
The trap flag TRPF is set either by HW, if
TRPPEN = 1 and CTRAP = 0, or by SW. If
TRPM2 = 0, bit TRPF is reset by HW if the input
CTRAP becomes inactive (TRPPEN = 1). If
TRPM2 = 1, bit TRPF has to be reset by SW in order
to leave the trap state.
0 The trap condition has not occurred
1 The trap condition has occurred (CTRAP = 0
or by SW)
9
rh
Timer T13 Period-Match Flag
0 No T13 Period-Match yet
1 A T13 Period-Match has occurred
8
rh
Timer T13 Compare-Match Flag
0 No T13 Compare-Match yet
1 A T13 Compare-Match has occurred
7
rh
Timer T12 Period-Match Flag
0 No T12 Period-Match yet
1 A T12 Period-Match has occurred while
counting up
6
rh
Timer T12 One-Match Flag
0 No T12 One-Match yet
1 A T12 One-Match has been detected while
counting down
User’s Manual
CAPCOM6_X, V2.0
18-73
V2.1, 2004-03