English
Language : 

XC164-16 Datasheet, PDF (164/417 Pages) Infineon Technologies AG – 16-Bit Single-Chip Microcontroller with C166SV2 Core Volume 2 (of 2): Peripheral Units
XC164-16 Derivatives
Peripheral Units (Vol. 2 of 2)
Capture/Compare Unit 6 (CAPCOM6)
Register T12MSEL contains control bits to select the capture/compare functionality of
the three channels of Timer T12.
CCU6_T12MSEL
T12 Mode Select Register
XSFR (E8C6H/--)
Reset Value: 0000H
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
----
----
MSEL62
rw
MSEL61
rw
MSEL60
rw
Field
MSEL62
MSEL61
MSEL60
Bits
[11:8]
[7:4]
[3:0]
Type
rw
Description
Capture/Compare Mode Selection
These bitfields select the operating mode of the three
T12 capture/compare channels. Each channel (x = 0,
1, 2) can be programmed individually for one of these
modes (except for Hall Sensor Mode). See
Table 18-2.
Table 18-2 Capture/Compare Modes Overview
MSEL6x Selected Operating Mode
0000B
0001B
0010B
0011B
01XXB
1000B
Compare outputs disabled, pins CC6x and COUT6x can be used for IO.
Compare output on pin CC6x, pin COUT6x can be used for IO.
Compare output on pin COUT6x, pin CC6x can be used for IO.
Compare output on pins COUT6x and CC6x.
Double-Register Capture modes, see Chapter 18.1.4 and Table 18-3.
Hall Sensor Mode, see Chapter 18.5. In order to properly enable this mode,
all three MSEL6x fields have to be programmed to Hall Sensor mode.
1001B
101XB
11XXB
Hysteresis-like mode, see Chapter 18.1.5.
Multi-Input Capture modes, see Chapter 18.1.4 and Table 18-4.
Note: Channel status information is available through the channel state (modification)
registers, described in Section 18.3.
User’s Manual
CAPCOM6_X, V2.0
18-20
V2.1, 2004-03