Capture/Compare Unit 6 (CAPCOM6)
Register T12DTC controls the dead-time generation for the T12 compare channels.
Each channel can be independently enabled/disabled for dead-time generation. If
enabled, the transition from passive state to active state is delayed by the value defined
by bitfield DTM.
CCU6_T12DTC
T12 Dead-Time Control Reg.
XSFR (E894H/--)
Reset Value: 0000H
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
-
DTR DTR DTR
210
-
DTE DTE DTE
210
-
-
- rh rh rh - rw rw rw - -
DTM
rw
Field
DTR2
DTR1
DTR0
DTE2
DTE1
DTE0
DTM
Bits Type Description
14, rh
13,
12
Dead Time Run Indication Flags
Indicate the status of the dead-time generation for
each corresponding compare channel (0, 1, 2)
0 The dead-time counter is stopped
1 The dead-time counter is running (delay is
active)
10, rw
9,
8
Dead-Time Generation Enable Bits
Enable/disable the dead-time generation for each
corresponding compare channel (0, 1, 2)
0 Dead-time generation is disabled
1 Dead-time generation is enabled
[5:0] rw
Dead-Time Value
DTM specifies the programmable delay between
switching from the passive state to the active state of
the selected outputs
Note: The Dead-Time Counters can be cleared by setting bit DTRES in register TCTR4.