EP1SGX10DF672C6 Datasheet, PDF (239/272 Pages) Altera Corporation – Section I. Stratix GX Device Family Data Sheet
DC & Switching Characteristics
Table 6–52 shows the external I/O timing parameters when using
regional clock networks.
Table 6–52. Stratix GX Regional Clock External I/O Timing Parameters Notes (1), (2)
Symbol
tINSU
tINH
tOUTCO
tINSUPLL
tINHPLL
tOUTCOPLL
Parameter
Conditions
Setup time for input or bidirectional pin using column IOE
input register with regional clock fed by CLK pin
Hold time for input or bidirectional pin using column IOE
input register with regional clock fed by CLK pin
Clock-to-output delay output or bidirectional pin using
column IOE output register with regional clock fed by CLK
pin
CL O A D = 10 pF
Setup time for input or bidirectional pin using column IOE
input register with regional clock fed by Enhanced PLL with
default phase setting
Hold time for input or bidirectional pin using column IOE
input register with regional clock fed by Enhanced PLL with
default phase setting
Clock-to-output delay output or bidirectional pin using
column IOE output register with regional clock Enhanced
PLL with default phase setting
CL O A D = 10 pF
Notes to Table 6–52:
(1) These timing parameters are sample-tested only.
(2) These timing parameters are for column IOE pins. Row IOE pins are 100- to 250-ps slower depending on device,
speed grade, and the specific parameter in question. You should use the Quartus II software to verify the external
timing for any pin.
Table 6–53 shows the external I/O timing parameters when using global
clock networks.
Table 6–53. Stratix GX Global Clock External I/O Timing Parameters (Part 1 of 2) Notes (1), (2)
Symbol
tINSU
tINH
tOUTCO
tINSUPLL
Parameter
Conditions
Setup time for input or bidirectional pin using column IOE
input register with global clock fed by CLK pin
Hold time for input or bidirectional pin using column IOE
input register with global clock fed by CLK pin
Clock-to-output delay output or bidirectional pin using
CL O A D = 10 pF
column IOE output register with global clock fed by CLK pin
Setup time for input or bidirectional pin using column IOE
input register with global clock fed by Enhanced PLL with
default phase setting
Altera Corporation
June 2006
6–37