63
MMU and RESET
During RESET, all bits of the CA field of CBAR are set to 1 while all bits
of the BA field of CBAR, CBR and BBR are reset to 0. The logical 64KB
address space corresponds directly with the first 64KB 0000H to FFFFH)
of the 1024KB 00000H. to FFFFFH) physical address space. Thus, after
RESET, the Z8X180 begins execution at logical and physical address 0.
MMU Register Access Timing
When data is written into CBAR, CBR or BBR, the value is effective
from the cycle immediately following the I/O write cycle which updates
these registers.
During MMU programming insure that CPU program execution is not
disrupted. The next cycle following MMU register programming is
normally an Op Code fetch from the newly translated address. One
technique is to localize all MMU programming routines in a Common
Area that is always enabled.