English
Language : 

Z80180 Datasheet, PDF (138/326 Pages) Zilog, Inc. – Z8018x Family MPU
Z 8018x Fam ily
M PU Us e r M anual
123
ASCI Control Register A0, 1 (CNTLA0, 1)
Each ASCI channel Control Register A configures the major operating modes
such as receiver/transmitter enable and disable, data format, and multiprocessor
communication mode.
ASCI Status Register 1 (STAT1: 05H)
Bit
7
6
5
4
3
2
1
0
Bit/Field RDRF OVRN PE
FE
RIE CTS1E TDRE TIE
R/W
R
R
R
R
R/W R/W
R
R/W
Reset
0
0
0
0
0
0
0
0
Note: R = Read W = Write X = Indeterminate ? = Not Applicable
Bit
Position Bit/Field R/W
7
RDRF R
6
OVRN R
5
PE
R
Value Description
Receive Data Register Full — RDRF is set to 1 when an
incoming data byte is loaded into RDR. Note that if a
framing or parity error occurs, RDRF is still set and the
receive data (which generated the error) is still loaded
into RDR. RDRF is cleared to 0 by reading RDR, when
the DCD0 input is High, in IOSTOP mode, and during
RESET.
Overrun Error — OVRN is set to 1 when RDR is full
and RSR becomes full. OVRN is cleared to 0 when the
EFR bit (Error Flag Reset) of CNTLA is written to 0,
when DCD0 is High, in IOSTOP mode, and during
RESET.
Parity Error — PE is set to 1 when a parity error is
detected on an incoming data byte and ASCI parity
detection is enabled (the MOD1 bit of CNTLA is set to
1). PE is cleared to 0 when the EFR bit (Error Flag Reset)
of CNTLA is written to 0, when DCD0 is High, in
IOSTOP mode, and during RESET.
UM005001-ZMP0400