AC CHARACTERISTICS— Z8S180
Table 31. Z8S180 AC Characteristics VDD = 5V ±10% or VDD = 3.3V
±10%; 33-MHz Characteristics Apply Only to 5V Operation
Z8S180— 20 Z8S180— 33
MHz
MHz
No. Symbol Item
Min Max Min Max Unit
1
tCYC Clock Cycle Time
50 DC 30 DC ns
2
tCHW Clock “H” Pulse Width
15 —
10 —
ns
3
tCLW Clock “L” Pulse Width
15 —
10 —
ns
4
tCF
Clock Fall Time
—
10 —
5
ns
5
tCR Clock Rise Time
—
10 —
5
ns
6
tAD PHI Rise to Address Valid Delay —
30 —
15
ns
7
tAS Address Valid to MREQ Fall or
5
—
5
—
ns
IORQ Fall)
8
tMED1 PHI Fall to MREQ Fall Delay
—
25 —
15
ns
9
tRDD1 PHI Fall to RD Fall Delay IOC = 1 —
25 —
15
ns
PHI Rise to RD Rise Delay IOC = —
25 —
15
0
10
tM1D1 PHI Rise to M1 Fall Delay
—
35 —
15
ns
11
tAH Address Hold Time from
5
—
5
—
ns
MREQ, IOREQ, RD, WR High
12
tMED2 PHI Fall to MREQ Rise Delay
—
25 —
15
ns