Z80180 Datasheet, PDF (25/326 Pages) Zilog, Inc. – Z8018x Family MPU
Z 8018x Fam ily
M PU Us e r M anual
10
RTS0. Request to Send 0 (Output, Active Low). This output is a
programmable modem control signal for ASCI channel 0.
RXA0, RXA1. Receive Data 0 and 1 (Inputs, Active High). These signals
are the receive data to the ASCI channels.
RXS. Clocked Serial Receive Data (Input, Active High). This line is the
receiver data for the CSIO channel. RXS is multiplexed with the CTS1
signal for ASCI channel 1.
ST. Status (Output, Active High). This signal is used with the M1 and
HALT output to decode the status of the CPU machine cycle. Table 1
provides status summary.
Table 1. Status Summary
ST HALT M1 Operation
0
1
0
1
1
0
1
1
1
0
X1
1
0
0
0
1
0
1
1. X = Don't care
CPU operation (1st Op Code fetch)
CPU operation (2nd Op Code and 3rd Op Code fetch)
CPU operation (MC2 except for Op Code fetch)
DMA operation
HALT mode
SLEEP mode (including SYSTEM STOP mode)
2. MC = Machine cycle
TEND0, TEND1. Transfer End 0 and 1 (Outputs, Active Low). This
output is asserted active during the last write cycle of a DMA operation. It
is used to indicate the end of the block transfer. TEND0 in multiplexed
with CKA1.
TEST. Test (Output, not on DIP version). This pin is for test and must be
left open.
UM005001-ZMP0400