204
AC Characteristics
The section provides information about the AC characteristics and timing of the eZ80L92.
All AC timing information assumes a standard load of 50 pF on all outputs. See Table 129.
Note: All data is preliminary and subject to change following completion of production
characterization.
Symbol Parameter
TXIN
System Clock
Cycle Time
TXINH System Clock
High Time
TXINL
System Clock
Low Time
TXINR System Clock
Rise Time
TXINF System Clock
Fall Time
Table 129. AC Characteristics
TA =
0ºC to 70ºC
Min
Max
20
TA =
–40ºC to 105ºC
Min
Max
20
Units
ns
Conditions
VDD = 3.0 – 3.6V
10
10
ns VDD = 3.0 – 3.6V;
TCLK = 50ns
10
10
ns VDD = 3.0 – 3.6V;
TCLK = 50ns
3
3
ns VDD = 3.0 – 3.6V;
TCLK = 50ns
3
3
ns VDD = 3.0 – 3.6V;
TCLK = 50ns
PS013012-1004