175
Table 96. ZDI Read/Write Control Register Functions (ZDI_RW_CTL = 16h in the ZDI
Register Write-Only Address Space) (Continued)
Hex
Value
Command
Hex
Value
Command
06
Read SP
86
Write SP
In ADL mode, SP = SPL.
In ADL mode, SP = SPL.
In Z80 mode, SP = SPS.
In Z80 mode, SP = SPS.
07
Read PC
87
Write PC
ZDI_RD_U ← PC[23:16]
PC[23:16] ← ZDI_WR_U
ZDI_RD_H ← PC[15:8]
PC[15:8] ← ZDI_WR_H
ZDI_RD_L ← PC[7:0]
PC[7:0] ← ZDI_WR_L
08
Set ADL
ADL ← 1
88
Reserved
09
Reset ADL
ADL ← 0
89
Reserved
0A
Exchange CPU register sets 8A
Reserved
AF ← AF’
BC ← BC’
DE ← DE’
HL ← HL’
0B
Read memory from current 8B
Write memory from current PC
PC value, increment PC
value, increment PC
Note: The eZ80® CPU’s alternate register set (A’, F’, B’, C’, D’, E’, HL’) cannot be read directly. The