eZ80L92 MCU
Product Specification
173
ZDI Write Data Registers
These three registers are used in the ZDI Write-Only register address space to store the
data that is written when a Write instruction is sent to the ZDI Read/Write Control register
(ZDI_RW_CTL). The ZDI Read/Write Control register is located at ZDI address 16h
immediately following the ZDI Write Data registers. As a result, the ZDI Master is
allowed to write the data to {ZDI_WR_U, ZDI_WR_H, ZDI_WR_L} and the Write com-
mand in one data transfer operation. See Table 95.
Table 95. ZDI Write Data Registers (ZDI_WR_U = 13h, ZDI_WR_H = 14h, and
ZDI_WR_L = 15h in the ZDI Register Write-Only Address Space)
Bit
7
6
5
4
3
2
1
0
Reset
X
X
X
X
X
X
X
X
CPU Access
W
W
W
W
W
W
W
W
Note: X = Undefined; W = Write.
Bit
Position
[7:0]
ZDI_WR_L,
ZDI_WR_H,
or
ZDI_WR_L
Value Description
00h–
FFh
These registers contain the data that is written during
execution of a Write operation defined by the
ZDI_RW_CTL register. The 24-bit data value is stored as
{ZDI_WR_U, ZDI_WR_H, ZDI_WR_L}. If less than 24 bits
of data are required to complete the required operation,
the data is taken from the least significant byte(s).
PS013012-1004
PRELIMINARY
ZiLOG Debug Interface