English
Language : 

MC68HC08AZ60 Datasheet, PDF (381/452 Pages) Motorola, Inc – Advance Information
Freescale Semiconductor, Inc.
Timer Interface Module A (TIMA-6)
I/O Registers
TOF — TIMA Overflow Flag Bit
This read/write flag is set when the TIMA counter resets to $0000 after
reaching the modulo value programmed in the TIMA counter modulo
registers. Clear TOF by reading the TIMA status and control register
when TOF is set and then writing a logic 0 to TOF. If another TIMA
overflow occurs before the clearing sequence is complete, then
writing logic 0 to TOF has no effect. Therefore, a TOF interrupt
request cannot be lost due to inadvertent clearing of TOF. Reset
clears the TOF bit. Writing a logic 1 to TOF has no effect.
1 = TIMA counter has reached modulo value.
0 = TIMA counter has not reached modulo value.
TOIE — TIMA Overflow Interrupt Enable Bit
This read/write bit enables TIMA overflow interrupts when the TOF bit
becomes set. Reset clears the TOIE bit.
1 = TIMA overflow interrupts enabled
0 = TIMA overflow interrupts disabled
TSTOP — TIMA Stop Bit
This read/write bit stops the TIMA counter. Counting resumes when
TSTOP is cleared. Reset sets the TSTOP bit, stopping the TIMA
counter until software clears the TSTOP bit.
1 = TIMA counter stopped
0 = TIMA counter active
NOTE:
Do not set the TSTOP bit before entering wait mode if the TIMA is
required to exit wait mode. Also, when the TSTOP bit is set and input
capture mode is enabled, input captures are inhibited until TSTOP is
cleared.
TRST — TIMA Reset Bit
Setting this write-only bit resets the TIMA counter and the TIMA
prescaler. Setting TRST has no effect on any other registers.
Counting resumes from $0000. TRST is cleared automatically after
the TIMA counter is reset and always reads as logic 0. Reset clears
the TRST bit.
1 = Prescaler and TIMA counter cleared
0 = No effect
19-tima-6
MOTOROLA
MC68HC08AZ60 — Rev 1.0
Timer Interface Module A (TIMA-6)
381
For More Information On This Product,
Go to: www.freescale.com