English
Language : 

MC9S12HY64 Datasheet, PDF (628/792 Pages) Freescale Semiconductor, Inc – S12 Microcontrollers
64 KByte Flash Module (S12FTMRC64K1V1)
Table 17-14. FSTAT Field Descriptions
Field
Description
7
CCIF
Command Complete Interrupt Flag — The CCIF flag indicates that a Flash command has completed. The
CCIF flag is cleared by writing a 1 to CCIF to launch a command and CCIF will stay low until command
completion or command violation.
0 Flash command in progress
1 Flash command has completed
5
ACCERR
Flash Access Error Flag — The ACCERR bit indicates an illegal access has occurred to the Flash memory
caused by either a violation of the command write sequence (see Section 17.4.3.2) or issuing an illegal Flash
command. While ACCERR is set, the CCIF flag cannot be cleared to launch a command. The ACCERR bit is
cleared by writing a 1 to ACCERR. Writing a 0 to the ACCERR bit has no effect on ACCERR.
0 No access error detected
1 Access error detected
4
FPVIOL
Flash Protection Violation Flag —The FPVIOL bit indicates an attempt was made to program or erase an
address in a protected area of P-Flash or D-Flash memory during a command write sequence. The FPVIOL
bit is cleared by writing a 1 to FPVIOL. Writing a 0 to the FPVIOL bit has no effect on FPVIOL. While FPVIOL
is set, it is not possible to launch a command or start a command write sequence.
0 No protection violation detected
1 Protection violation detected
3
MGBUSY
Memory Controller Busy Flag — The MGBUSY flag reflects the active state of the Memory Controller.
0 Memory Controller is idle
1 Memory Controller is busy executing a Flash command (CCIF = 0)
2
RSVD
Reserved Bit — This bit is reserved and always reads 0.
1–0
Memory Controller Command Completion Status Flag — One or more MGSTAT flag bits are set if an error
MGSTAT[1:0] is detected during execution of a Flash command or during the Flash reset sequence. See Section 17.4.5,
“Flash Command Description,” and Section 17.6, “Initialization” for details.
17.3.2.8 Flash Error Status Register (FERSTAT)
The FERSTAT register reflects the error status of internal Flash operations.
Offset Module Base + 0x0007
7
6
5
4
3
2
1
R
0
0
0
0
0
0
DFDIF
W
Reset
0
0
0
0
0
0
0
= Unimplemented or Reserved
Figure 17-12. Flash Error Status Register (FERSTAT)
All flags in the FERSTAT register are readable and only writable to clear the flag.
0
SFDIF
0
MC9S12HY/HA-Family Reference Manual, Rev. 1.04
628