Inter-Integrated Circuit (IICV3) Block Description
clock and the SCL period it may be necessary to wait until the IIC is busy after writing the calling address
to the IBDR before proceeding with the following instructions. This is illustrated in the following example.
An example of a program which generates the START signal and transmits the first byte of data (slave
address) is shown below:
CHFLAG
TXSTART
IBFREE
BRSET
BSET
MOVB
BRCLR
IBSR,#$20,*
IBCR,#$30
CALLING,IBDR
IBSR,#$20,*
;WAIT FOR IBB FLAG TO CLEAR
;SET TRANSMIT AND MASTER MODE;i.e. GENERATE START CONDITION
;TRANSMIT THE CALLING ADDRESS, D0=R/W
;WAIT FOR IBB FLAG TO SET
10.7.1.3 Post-Transfer Software Response
Transmission or reception of a byte will set the data transferring bit (TCF) to 1, which indicates one byte
communication is finished. The IIC bus interrupt bit (IBIF) is set also; an interrupt will be generated if the
interrupt function is enabled during initialization by setting the IBIE bit. Software must clear the IBIF bit
in the interrupt routine first. The TCF bit will be cleared by reading from the IIC bus data I/O register
(IBDR) in receive mode or writing to IBDR in transmit mode.
Software may service the IIC I/O in the main program by monitoring the IBIF bit if the interrupt function
is disabled. Note that polling should monitor the IBIF bit rather than the TCF bit because their operation
is different when arbitration is lost.
Note that when an interrupt occurs at the end of the address cycle the master will always be in transmit
mode, i.e. the address is transmitted. If master receive mode is required, indicated by R/W bit in IBDR,
then the Tx/Rx bit should be toggled at this stage.
During slave mode address cycles (IAAS=1), the SRW bit in the status register is read to determine the
direction of the subsequent transfer and the Tx/Rx bit is programmed accordingly.For slave mode data
cycles (IAAS=0) the SRW bit is not valid, the Tx/Rx bit in the control register should be read to determine
the direction of the current transfer.
The following is an example of a software response by a 'master transmitter' in the interrupt routine.
ISR
TRANSMIT
BCLR
BRCLR
BRCLR
BRSET
MOVB
IBSR,#$02
IBCR,#$20,SLAVE
IBCR,#$10,RECEIVE
IBSR,#$01,END
DATABUF,IBDR
;CLEAR THE IBIF FLAG
;BRANCH IF IN SLAVE MODE
;BRANCH IF IN RECEIVE MODE
;IF NO ACK, END OF TRANSMISSION
;TRANSMIT NEXT BYTE OF DATA
10.7.1.4 Generation of STOP
A data transfer ends with a STOP signal generated by the 'master' device. A master transmitter can simply
generate a STOP signal after all the data has been transmitted. The following is an example showing how
a stop condition is generated by a master transmitter.