English
Language : 

MC9S12HY64 Datasheet, PDF (402/792 Pages) Freescale Semiconductor, Inc – S12 Microcontrollers
Pulse-Width Modulator (S12PWM8B8CV1)
NOTE
When PWMSCLA = $00, PWMSCLA value is considered a full scale value
of 256. Clock A is thus divided by 512.
Any value written to this register will cause the scale counter to load the new scale value (PWMSCLA).
Module Base + 0x0008
7
6
5
4
3
2
1
0
R
Bit 7
6
5
4
3
2
1
Bit 0
W
Reset
0
0
0
0
0
0
0
0
Figure 11-11. PWM Scale A Register (PWMSCLA)
Read: Anytime
Write: Anytime (causes the scale counter to load the PWMSCLA value)
11.3.2.10 PWM Scale B Register (PWMSCLB)
PWMSCLB is the programmable scale value used in scaling clock B to generate clock SB. Clock SB is
generated by taking clock B, dividing it by the value in the PWMSCLB register and dividing that by two.
Clock SB = Clock B / (2 * PWMSCLB)
NOTE
When PWMSCLB = $00, PWMSCLB value is considered a full scale value
of 256. Clock B is thus divided by 512.
Any value written to this register will cause the scale counter to load the new scale value (PWMSCLB).
Module Base + 0x0009
7
6
5
4
3
2
1
0
R
Bit 7
6
5
4
3
2
1
Bit 0
W
Reset
0
0
0
0
0
0
0
0
Figure 11-12. PWM Scale B Register (PWMSCLB)
Read: Anytime
Write: Anytime (causes the scale counter to load the PWMSCLB value).
11.3.2.11 Reserved Registers (PWMSCNTx)
The registers PWMSCNTA and PWMSCNTB are reserved for factory testing of the PWM module and are
not available in normal modes.
MC9S12HY/HA-Family Reference Manual, Rev. 1.04
402
Freescale Semiconductor