English
Language : 

LM3S3748 Datasheet, PDF (618/753 Pages) List of Unclassifed Manufacturers – Microcontroller
Pulse Width Modulator (PWM)
Register 5: PWM Output Fault (PWMFAULT), offset 0x010
This register controls the behavior of the PWM outputs in the presence of fault conditions. Both the
fault inputs and debug events are considered fault conditions. On a fault condition, each PWM signal
can be passed through unmodified or driven to a specified value. For outputs that are configured
for pass-through, the debug event handling on the corresponding PWM generator also determines
if the PWM signal continues to be generated.
Fault condition control occurs before the output inverter, so PWM signals driven to a specified value
on fault are inverted if the channel is configured for inversion (therefore, the pin is driven to the
logical complement of the specified value on a fault condition).
PWM Output Fault (PWMFAULT)
Base 0x4002.8000
Offset 0x010
Type R/W, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
Type RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
reserved
Fault7 Fault6 Fault5 Fault4 Fault3 Fault2 Fault1 Fault0
Type RO
RO
RO
RO
RO
RO
RO
RO
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit/Field
31:8
7
6
5
4
3
2
Name
reserved
Fault7
Fault6
Fault5
Fault4
Fault3
Fault2
Type
RO
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0x00
0
0
0
0
0
0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
PWM7 Fault
When set, the PWM7 output signal is driven to a specified value on a
fault condition.
PWM6 Fault
When set, the PWM6 output signal is driven to a specified value on a
fault condition.
PWM5 Fault
When set, the PWM5 output signal is driven to a specified value on a
fault condition.
PWM4 Fault
When set, the PWM4 output signal is driven to a specified value on a
fault condition.
PWM3 Fault
When set, the PWM3 output signal is driven to a specified value on a
fault condition.
PWM2 Fault
When set, the PWM2 output signal is driven to a specified value on a
fault condition.
618
April 08, 2008
Preliminary