M306H7MG-XXXFP Datasheet, PDF (49/329 Pages) Renesas Technology Corp – SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER with DATA ACQUISITION CONTROLLER
M306H7MG-XXXFP/MC-XXXFP/FGFP
6. INTERRUPTS
Interrupt control register (Note 2)
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
TB5IC
TB4IC/U1BCNIC (Note 3)
TB3IC/U0BCNIC (Note 3)
BCNIC
DM0IC, DM1IC
ADIC
S0TIC to S2TIC
S0RIC to S2RIC
TA0IC to TA4IC
TB0IC to TB2IC
Address
004516
004616
004716
004A16
004B16, 004C16
004E16
005116, 005316, 004F16
005216, 005416, 005016
005516 to 005916
005A16 to 005C16
After reset
XXXXX0002
XXXXX0002
XXXXX0002
XXXXX0002
XXXXX0002
XXXXX0002
XXXXX0002
XXXXX0002
XXXXX0002
XXXXX0002
Bit symbol
Bit name
Function
RW
ILVL0 Interrupt priority level
select bit
b2 b1 b0
RW
0 0 0 : Level 0 (interrupt disabled)
0 0 1 : Level 1
ILVL1
0 1 0 : Level 2
0 1 1 : Level 3
RW
1 0 0 : Level 4
1 0 1 : Level 5
ILVL2
1 1 0 : Level 6
1 1 1 : Level 7
RW
IR
Interrupt request bit
0 : Interrupt not requested
1 : Interrupt requested
RW
(Note 1)
(b7-b4)
No functions are assigned.
When writing to these bits, write “0”. The values in these bits
when read are indeterminate.
Note 1: This bit can only be reset by writing "0" (Do not write "1").
Note 2: To rewrite the interrupt control registers, do so at a point that does not generate the interrupt request for that
register. For details, see the precautions for interrupts.
Note 3: Use the IFSR2A register to select.
b7 b6 b5 b4 b3 b2 b1 b0
0
Symbol
INT3IC
S4IC/INT5IC
S3IC/INT4IC
INT0IC to INT2IC
Address
004416
004816
004916
005D16 to 005F16
After reset
XX00X0002
XX00X0002
XX00X0002
XX00X0002
Bit symbol
Bit name
Function
RW
ILVL0 Interrupt priority level
select bit
b2 b1 b0
0 0 0 : Level 0 (interrupt disabled)
RW
0 0 1 : Level 1
ILVL1
0 1 0 : Level 2
0 1 1 : Level 3
1 0 0 : Level 4
RW
1 0 1 : Level 5
ILVL2
1 1 0 : Level 6
1 1 1 : Level 7
RW
IR
Interrupt request bit
POL
Polarity select bit
0: Interrupt not requested
1: Interrupt requested
0 : Selects falling edge (Notes 3, 4)
1 : Selects rising edge
RW
(Note 1)
RW
Reserved bit
Must always be set to “0”
RW
No functions are assigned.
(b7-b6)
When writing to these bits, write “0”. The values in these bits
RW
when read are indeterminate.
Note 1: This bit can only be reset by writing "0" (Do not write "1").
Note 2: To rewrite the interrupt control register, do so at a point that does not generate the interrupt request for that
register. For details, see the precautions for interrupts.
Note 3: If the IFSR register’s IFSRi bit (i = 0 to 5) is "1" (both edges), set the INTiIC register’s POL bit to "0 "(falling
edge).
Note 4: Set the S3IC or S4IC register’s POL bit to "0" (falling edge) when the IFSR register’s IFSR6 bit = 0 (SI/O3
selected) or IFSR7 bit = 0 (SI/O4 selected), respectively
.
Figure 6.3 Interrupt Control Registers
Rev.2.10 Oct 25, 2006 Page 49 of 326
REJ03B0152-0210